Skip to content
OI

OKO ICARE SOLUTIONS PRIVATE LIMITED

Nagpur, Maharashtra

DPIIT recognised Locality Healthcare & Lifesciences

In their own words

Glaucoma is the second leading cause of preventable blindness worldwide. It is progressive, asymptomatic disease of optic nerve associated with a vision loss. According to Glaucoma Society of India, 12 million people are affected by Glaucoma 12.8 of total cases of blindness . About 50 of Glaucoma patients go undetectable until they lose substantial vision and suffer from irreversible loss of visual function if untreated. In the normal eye, ciliary body procedure aqueous humour, it is drained at constant rate from the eye. In most types of glaucoma, the eye drainage system becomes clogged so the intraocular fluid cannot drain. As the fluid builds up, it causes pressure to build inside the eye. High pressure damages the sensitive optic nerve and results in vision loss Any blockage produced in the drainage system of the eye increases the intraocular pressure IOP of the eye. IOP of an eyeball is a key indicator for Glaucoma, although the advanced treatments are available for glaucoma patients, detection is the major problem. Devices those are available for the measurement of IOP records the IOP of patients over cornea. It requires expert clinician and anesthesia. In rural and remote areas hardly the aid of expert Ophthalmologist is available because of it the patients having elevated IOP remains undetected and only came to know after losing eyesight. There should be certain measures to detect the elevated IOP so that the further damage to patients eyesight can be avoided. Thus, there is a dire need for a cost-effective intraocular measurement device for early detection and management of glaucoma. A novel method is proposed to measure IOP using both applanation and indentation principles by Glaucoma screener. The measuring probe touches the eyelid instead of cornea that is trans-palpebral way. This device can be placed on closed eyelid by applying a sufficient pressure applanation force on the eyelid through a plunger with its tip. The calibrated scale is designed to indicate the IOP of patients eye. This medical device inbuilt with pressure sensors to detect Glaucoma at very early stage without anesthesia.

Written by the company on its public Startup India profile. Not verified by us.

What the record says

DPIIT recognition number
DIPP47640
CIN
U33309PN2019PTC185610
Incorporated (MCA)
2019
Registered on Startup India
2019
Self-declared stage
Prototype
MCA status
Active
Company class
Private
Registrar
RoC-Pune
Authorised capital
₹10,00,000
Paid-up capital
₹1,08,330

okoicaresolutions.com/

Funding signals

We hold evidence classes, not rounds. There is no amount, no date and no valuation here because we do not have them.

Where this is

Locality

Nagpur

Maharashtra

We know the area but not the address. The pin below covers roughly a kilometre.

Geocode confidence: low

See all Nagpur startups on the map

Is this your company?

Everything here comes from public government records. If something is wrong, the authoritative place to correct it is the Startup India portal itself, and we will pick the correction up on the next monthly snapshot. To flag an error on our side, write to trust@indianstartupmap.com.

How we built this record